Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Braz. dent. j ; 34(4): 107-114, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520335

ABSTRACT

Abstract This study evaluated color stability (CS), anti-adherence effect (AAE), and cell viability of microorganisms on acrylic resin (AR) surface, treated associated or not with sodium percarbonate (SP). AR specimens were prepared, and color analysis was performed before and after the treatments and the CS was calculated. For analysis of AAE, the samples were sterilized by radiation in a microwave oven. Then samples were randomly distributed: phosphate-buffered saline (PBS - control), 0.5% sodium hypochlorite (SH), phytosphingosine (PHS), and phytosphingosine + SP (PHS+Na2CO3). The specimens remained in contact with solutions for 30 minutes and were later contaminated by Candida albicans. Aliquots were seeded in Petri dishes with Sabouraud Dextrose agar and incubated at 37°C for 24 hours. After the incubation, the number of colonies was counted. The cell viability of adhered microorganisms on the AR was evaluated and 20 fields were observed under an epifluorescence microscope, and the percentage of adhered viable cells was calculated. Data were compared (One-way ANOVA, Tukey, p<.05). As for CS, PHS+ Na2CO3 (0.4±0.1) resulted in less change than PBS (0.9±0.2), similar to the other groups (SH [1.0±0.3)]; PHS [0.9±0.2)]). There was no difference for all tested solutions regarding the ability to avoid microorganism adherence (p>0.05), but PHS (11.2±4.1) resulted in a smaller area of adhered viable cells, statistically different from SH (18.2±7.6) and PBS (26.4±10.8). It was concluded that PHS resulted in lower adhered viable cells and when associated with Na2CO3, also shows a lower effect on the CS of AR.


Resumo Este estudo avaliou estabilidade de cor (EC), efeito antiaderente (EAA) e viabilidade celular de microrganismos em superfície de resina acrílica (RA), tratada com solução de fitoesfingosina, associada ou não ao percarbonato de sódio (PS). Espécimes RA foram preparados e análise de cor foi realizada antes e após os tratamentos e EC foi calculada. Para análise de EAA, as amostras foram esterilizadas por radiação em forno de micro-ondas. Então foram distribuídas aleatoriamente: solução salina tamponada com fosfato (PBS - controle), hipoclorito de sódio 0,5% (SH), fitoesfingosina (PHS) e fitoesfingosina + SP (PHS+Na2CO3). Os espécimes permaneceram em contato com as soluções por 30 minutos e posteriormente foram contaminados por Candida albicans. Alíquotas foram semeadas em placas de Petri com ágar Sabouraud Dextrose e incubadas a 37°C por 24 horas. Após a incubação, o número de colônias foi contado. A viabilidade celular dos microorganismos aderidos na RA foi avaliada e 20 campos foram observados em microscópio de epifluorescência, e a porcentagem de células viáveis aderidas foi calculada. Os dados foram comparados (One-way ANOVA, Tukey, p<0,05). Quanto a EC, o PHS+ Na2CO3 [0,4 (0,1)] resultou em menor alteração que o PBS [0,9 (0,2)], semelhante aos demais grupos (SH [1,0 (0,3)]; PHS [0,9 (0,2)]). Não houve diferença para todas as soluções testadas quanto à capacidade de evitar a aderência de microorganismos (p>0,05), mas o PHS [11,2 (4,1)] resultou em uma área menor de células viáveis aderidas, estatisticamente diferente do SH [18,2 (7,6)] e PBS [26,4 (10,8)]. Concluiu-se que o PHS resultou em menor número de células viáveis aderidas e, quando associado ao Na2CO3, também apresenta menor efeito sobre o EC da RA.

2.
Braz. dent. j ; 34(2): 88-96, Mar.-Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439568

ABSTRACT

Abstract This study evaluated the effect of phytosphingosine (PHS) and bioactive glass-ceramic (Biosilicate) on dental enamel in terms of color alteration (ΔE), microhardness, and surface roughness when submitted to erosive challenge (EC). Sixty specimens of bovine teeth (6×6×2mm) were obtained. Initial color (Easyshade, VITA), KHN (HMV-2, Shimadzu), and Ra (SJ-201P, Mitutoyo) measurements were performed. Specimens were separated into groups according to treatments: PHS, 10% Biosilicate, PHS+10% Biosilicate, and artificial saliva (control) and submitted to EC with Coca-Cola for 2 min. This cycle was repeated 4 times daily/15 days. Between cycles, specimens remained in artificial saliva (2 h/37°C). After daily cycles, they were also stored in artificial saliva at 37ºC. Final color, microhardness, and surface roughness measurements were done. Color and KHN data were analyzed by one-way ANOVA, Tukey's test; and Ra, by 2-way ANOVA, repeated measures, and Tukey's test (p<.05). The highest ΔE occurred in Saliva+EC (p<.05). Groups treated with PHS presented lower color change than Saliva+EC (p<.05). All the groups presented mean values above the 50:50% perceptibility (50:50%PT) and acceptability (50:50%AT) thresholds, except for control that showed mean value above 50:50%PT but below 50:50%AT. Biosilicate+EC showed higher relative microhardness than Saliva+EC (p<.05), but was similar to PHS+EC and PHS+Biosilicate+EC. Final enamel surface roughness increased for all the groups (p<.05), except for the control. The Biosilicate may prevent enamel mineral loss induced by erosion better than saliva. The PHS associated or not to Biosilicate demonstrated better color stability than saliva.


Resumo Este estudo avaliou o efeito da Fitoesfingosina (PHS) e da vitrocerâmica bioativa (Biosilicato) sobre o esmalte dental em termos de alteração de cor (ΔE), microdureza (KHN) e rugosidade superficial, quando submetido a desafio erosivo (DE). Sessenta espécimes de dentes bovinos (6×6×2mm) foram obtidos. Foram realizadas leituras de cor inicial (Easyshade, VITA), microdureza (HMV-2, Shimadzu) e rugosidade superfícial (SJ-201P, Mitutoyo). Os espécimes foram separados em grupos de acordo com os tratamentos: PHS, Biosilicato a 10%, PHS+Biosilicato a 10%, e saliva artificial (controle). Em seguida, foram submetidos a DE com Coca-Cola por 2 min. Esse ciclo foi repetido 4 vezes/dia por 15 dias. Entre os ciclos, as amostras foram mantidas em saliva artificial (2 h/37°C). Após os ciclos diários, os espécimes também foram armazenados em saliva artificial a 37ºC. Foram realizadas leituras finais de cor, microdureza e rugosidade superficial. Os dados de cor e microdureza foram analisados ​​por ANOVA de uma via, teste de Tukey; e dados de rugosidade superficial, por ANOVA de duas vias, teste de Tukey (p<.05). A maior ΔE ocorreu em Saliva+DE (p<.05). Grupos tratados com PHS apresentaram menor alteração de cor do que Saliva+DE (p<.05). Biosilicate+DE demonstrou valores intermediários, similar (p>.05) aos outros grupos, exceto Saliva+DE. Todos os grupos presentaram média acima dos limites 50:50% de perceptibilidade (50:50%LP) e aceitabilidade (50:50%LA) exceto o controle que demonstrou média acima do 50:50%LA mas abaixo do 50:50%LP. Biosilicate+DE mostrou maior microdureza realativa do que Saliva+DE (p<.05), mas similar a PHS+DE e PHS+Biosilicato+DE. A rugosidade de superfície do esmalte aumentou para todos os grupos, exceto para o controle que presentou a menor alteração (p<.05). O Biosilicato apode prevenir perda mineral do esmalte indizido pela erosão melhor que a saliva. O PHS associado ou não ao Biosilicato demonstrou melhor estabilidade de cor que a saliva.

3.
Rev. Flum. Odontol. (Online) ; 1(60): 112-126, jan.-abr. 2023. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1411346

ABSTRACT

A descoloração ou perda de translucidez dos materiais cerâmicos usados em odontologia ainda hoje é um problema, especialmente pelo comprometimento estético. Com o objetivo de comparar a estabilidade de cor, blocos de dissilicato de lítio (IPS e.max CAD HT) e de silicato de lítio reforçado com zircônia (Vita Suprinity HT) fresados no desenho de um disco com dimensões de 1,5 × 7 × 12 mm3 (n = 120) foram preparados usando 3 procedimentos de acabamento de superfície: glaze, polimento mecânico e coloração externa e glaze. Em seguida, cada grupo foi dividido em 2 subgrupos de armazenamento, chá preto e café (n = 10/grupo). As mensurações de cor foram medidas com espectrofotômetro (VITA Easyshade) no estágio inicial e após 1 semana, 2 semanas, 1 mês, 2 meses de armazenamento. As alterações de cor (ΔE) foram calculadas e analisadas estatisticamente usando ANOVA (α < 0,05). Observamos que, para ambos os materiais cerâmicos, o procedimento de glaze apresentou valores de mudança de cor estatisticamente menores do que os outros grupos (p < 0,05) após o armazenamento em ambas as bebidas. Os grupos de dissilicato de lítio apresentaram valores de alteração de cor estatisticamente menores em relação aos grupos de silicato de lítio reforçados com zircônia. Conclui-se que, o glaze sozinho levou a uma maior estabilidade de cor em relação ao polimento mecânico e coloração externa o dissilicato de lítio apresentou maior estabilidade de cor em comparação com o silicato de lítio reforçada com zircônia.


The discoloration or loss of translucency of ceramic materials used in dentistry is still a problem today, especially due to aesthetic compromise. In order to compare color stability, lithium disilicate (IPS e.max CAD HT) and zirconia-reinforced lithium silicate (Vita Suprinity HT) blocks were milled into a disc design with dimensions of 1.5 × 7 × 12 mm3 (n = 120). The specimens were prepared using 3 surface finishing procedures: glaze, mechanical polishing and external staining and glaze. Then, each group was divided into 2 storage subgroups, black tea and coffee (n = 10/group). Color measurements were measured with a spectrophotometer (VITA Easyshade) at the initial stage and after 1 week, 2 weeks, 1 month, 2 months of storage. Color changes (ΔE) were calculated and statistically analyzed using ANOVA (α < 0.05). We observed that, for both ceramic materials, the glaze procedure presented statistically lower color change values ​​than the other groups (p < 0.05) after storage in both beverages. The lithium disilicate groups showed statistically lower color change values ​​than the zirconia-reinforced lithium silicate groups. It is concluded that, glaze alone led to greater color stability compared to mechanical polishing and external staining, lithium disilicate showed greater color stability compared to zirconia-reinforced lithium silicate.


Subject(s)
Beverages , Ceramics , Computer-Aided Design , Color , Dental Polishing/methods , Lithium , Silicates
4.
Braz. dent. j ; 33(3): 55-66, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384030

ABSTRACT

Abstract The objective of this study was to evaluate the effect of natural bleaching products on the color, whiteness, and superficial properties of dental enamel. Seventy fragments of bovine teeth were obtained (6mm x 6mm x 2mm). Initial surface roughness (Surfcorder SE1700, Kosakalab), microhardness (HMV-2, Shimadzu), color (EasyShade, VITA), and surface gloss (Micro-Gloss 45º BYK, Gardner) readings were done. Samples were separated into five groups (n=14) according to the treatments used: CT-conventional toothpaste (negative control); CH-charcoal; TU-turmeric; BP-banana peel, and CP16%-16% carbamide peroxide gel (positive control, 4 h/day for 14 days), and then brushed for 560 cycles (T1) and 1200 cycles (T2), equivalent to 14 and 30 days of brushing. New measurements were performed after T1 and T2. The whiteness index for dentistry change (∆WID) and Weight loss (Wl) were calculated. CP16% demonstrated the highest (p<.05) color change (ΔE00) and ∆WID (2-way ANOVA, Bonferroni, p<.05). Surface gloss alterations were lower for TU, CP16%, and BP. CT and CH increased surface roughness (p<.05). CP16% decreased enamel microhardness. CH presented medium abrasiveness, and CT and TU, low abrasiveness. The popular bleaching products were not efficient for tooth whitening. Furthermore, brushing with charcoal increased the enamel surface roughness, and CP16% decreased enamel microhardness over time


Resumo O objetivo deste estudo foi avaliar o efeito de produtos clareadores naturais na cor, efeito clareador e propriedades superficiais do esmalte dentário. Setenta fragmentos de dente bovino foram obtidos (6mm x 6mm x 2mm). Foram realizadas leituras iniciais de rugosidade de superfície (Surfcorder SE1700, Kosakalab), microdureza (HMV-2, Shimadzu), cor (EasyShade, VITA) e brilho (Micro-Gloss 45º BYK, Gardner). As amostras foram separadas em cinco grupos (n=14), de acordo com os tratamentos utilizados: DC - dentifrício convencional (controle negativo); CA - carvão ativado; CM - cúrcuma; CB - casca de banana e PC16% - gel de peróxido de carbamida a 16% (controle positivo, 4h/dia por 14 dias), foram então escovadas por 560 ciclos (T1) e 1200 ciclos (T2), equivalente a 14 e 30 dias de escovação. Novas leituras foram realizadas após T1 e T2. A alteração do whiteness index for dentistry (∆WID) e perda de massa (Pm) foram calculadas. PC16% demonstrou a maior (p<0,05) alteração de cor (ΔE00) e ∆WID (2-way ANOVA, Bonferroni, p<0,05). A alteração de brilho foi menor para CM, PC16% e CB. DC e CA aumentaram a rugosidade de superfície (p<0,05). PC16% diminuiu a microdureza do esmalte. CA apresentou abrasividade média, e DC e CM, baixa abrasividade. Os produtos clareadores populares não foram eficientes para clareamento dental. Ademais, a escovação com carvão ativado aumentou a rugosidade de superfície do esmalte dentário, e com maior tempo PC16% diminuiu a microdureza do esmalte.

5.
Odovtos (En línea) ; 24(2)ago. 2022.
Article in English | LILACS, SaludCR | ID: biblio-1386595

ABSTRACT

Abstract The aim of this in vitro study was to compare the long-term effect of overnight use of denture cleansers with different chemical compositions on the color stability of denture base polymers (DBPs). The four DBPs evaluated were PEEK (PK group), thermoinjection-molded polyamide (PA group), auto-polymerized polymethylmethacrylate (PMMA) (AP group), and heat-polymerized resin PMMA (HP group). The cleaning agents used were Corega tablet (CT), Protefix tablet (PT), and 0.5% sodium hypochlorite (NaOCl) solution (SH). Distilled water (DW) served as a control. Forty-eight disc-shaped specimens (10mm × 2mm) were prepared from each DBP and randomly immersed in the different storage media (n=12 in each group). Color measurements of the specimens before and after immersion in the denture cleansers were made using a spectrophotometer (VITA Easyshade V). The color changes were measured and recorded in L* a* b*. After 120 d, the CIEDE2000 formula was used to calculate color changes (ΔE00). For analysis of the data, a multivariate analysis of variance was used (p<0.05). The results of the statistical analysis revealed significant color change differences in the DBPs immersed in the various denture cleansers (p<0.05). Groups PA and PK showed the highest values for all solutions. AP-SH showed the highest ΔE00 value in group AP, no significant difference was found between other solutions. In group HP, there was no statistically significant difference between the average ΔE00 values of all solutions. Long-term daily use of the denture cleansers affected the color stability of all the DBPs, although the level of color change was acceptable. Laboratory and clinical studies on the color stability of PEEK are needed to confirm the results of this study.


Resumen El objetivo de este estudio in vitro fue comparar el efecto a largo plazo del uso nocturno de limpiadores de prótesis con diferentes composiciones químicas sobre la estabilidad del color de los polímeros base de prótesis (DBP). Los cuatro DBP evaluados fueron PEEK (grupo PK), poliamida moldeada por termoinyección (grupo PA), polimetilmetacrilato (PMMA) autopolimerizado (grupo AP) y resina PMMA termopolimerizada (grupo HP). Los agentes de limpieza utilizados fueron Corega (CT), Protefix (PT) y la solución de hipoclorito de sodio (NaOCl) al 0,5% (SH). El agua destilada (DW) sirvió de control. Se prepararon 48 especímenes en forma de disco (10mm × 2mm) de cada DBP y se sumergieron al azar en los diferentes medios de almacenamiento (n=12 en cada grupo). Las mediciones del color de las muestras antes y después de la inmersión en los limpiadores de dentaduras se realizaron con un espectrofotómetro (VITA Easyshade V). Los cambios de color se midieron y registraron en L* a* b*. Después de 120 d, se utilizó la fórmula CIEDE2000 para calcular los cambios de color (ΔE00). Para el análisis de los datos, se utilizó un análisis multivariante de la varianza (p<0,05). Los resultados del análisis estadístico revelaron diferencias significativas en el cambio de color de los DBP sumergidos en los distintos limpiadores de dentaduras (p<0,05). Los grupos PA y PK mostraron los valores más altos para todas las soluciones. AP-SH mostró el valor ΔE00 más alto en el grupo AP, no se encontraron diferencias significativas entre las demás soluciones. En el grupo HP, no hubo diferencias estadísticamente significativas entre los valores medios de ΔE00 de todas las soluciones. El uso diario a largo plazo de los limpiadores de dentaduras afectó a la estabilidad del color de todos los DBP, aunque el nivel de cambio de color fue aceptable. Se necesitan estudios de laboratorio y clínicos sobre la estabilidad del color del PEEK para confirmar los resultados de este estudio.


Subject(s)
Polymers , Prosthesis Coloring , Denture Cleansers , Polymethyl Methacrylate
6.
Odovtos (En línea) ; 23(3)dic. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386563

ABSTRACT

ABSTRACT: CAD/CAM blocks are widely used in dental restorations around the world. This study aimed to investigate the effects of different polishing and finishing systems on surface roughness and color change of resin-based CAD/CAM blocks. In this study, material samples of 2×7×12mm were prepared. In three different experimental groups, surface polishing was carried out with one-step, two-step and multi-step polishing systems. The samples in one subgroup of each experimental group were polished with the diamond paste. Once the initial roughness and color values of the samples were measured using a profilometer and a spectrophotometer, the samples were immersed in coffee. Surface roughness and color change (ΔE00) results were statistically analyzed using two-way variance analysis (ANOVA). Finishing and polishing systems created significantly different levels of surface roughness on the hybrid ceramic block (Vita Enamic) but not on the composites block (Brilliant Crios, Grandio Blocs). While the two-step and multi-step finishing and polishing systems produced the lowest color change on hybrid ceramic blocks, one-step and two-step systems achieved this on composite blocks (p<0.05). In all test groups, the supplementary polishing performed after regular polishing procedures helped us reduce the surface roughness and color change on CAD/CAM blocks. The findings obtained in this study suggest that one and two-step polishing systems are more suitable for resin-based composite CAD/CAM blocks; for hybrid ceramic CAD/CAM blocks, on the other hand, two and multi-step finishing and polishing systems seem to be more efficient concerning lower surface roughness and resistance to color changes.


RESUMEN: Los bloques CAD/CAM son ampliamente utilizados en las restauraciones dentales, alrededor del mundo. El objetivo de este estudio es investigar los efectos de diferentes sistemas de pulido y acabado sobre la rugosidad de la superficie y el cambio de color de los bloques CAD/CAM de resina. En este estudio se prepararon muestras de material de 2×7×12mm. El pulido de la superficie se llevó a cabo en tres grupos experimentales con sistemas de pulido de un paso, de dos pasos y de varios pasos. Las muestras de un subgrupo de cada grupo experimental se pulieron con la pasta de diamante. Una vez medidos los valores iniciales de rugosidad y color de las muestras mediante un perfilómetro y un espectrofotómetro, las muestras se sumergieron en café. Los resultados de la rugosidad superficial y el cambio de color (ΔE00) se analizaron estadísticamente mediante un análisis de varianza de dos vías (ANOVA). Los sistemas de acabado y pulido crearon niveles de rugosidad superficial significativamente diferentes en el bloque cerámica híbrida (Vita Enamic) pero no en el bloque de composites (Brilliant Crios, Grandio Blocs). Mientras que los sistemas de acabado y pulido de dos y varios pasos produjeron el menor cambio de color en los bloques de cerámica híbrida, los sistemas de un paso y dos pasos lo consiguieron en los bloques de composite (p<0,05). En todos los grupos de prueba, el pulido suplementario realizado después de los procedimientos de pulido regulares nos ayudó a reducir la rugosidad de la superficie y el cambio de color en los bloques CAD/CAM. Los hallazgos obtenidos en este estudio sugieren que los sistemas de pulido de uno y dos pasos son más adecuados para los bloques CAD/CAM de resina; en cambio, para los bloques CAD/CAM de cerámica híbrida, los sistemas de acabado y pulido de dos y varios pasos parecen ser más eficientes en lo que respecta a la menor rugosidad de la superficie y la resistencia a los cambios de color.


Subject(s)
Resins, Synthetic , Color , Dental Restoration, Permanent/instrumentation
7.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386537

ABSTRACT

ABSTRACT: Purpose: The purpose of this study was to evaluate the discoloration of a dual-cure bulk-fill (DCBF) and light-cure bulk-fill (LCBF) composites relative to conventional composites (CC) after water and coffee immersion. Methods: One- hundred disc-shaped specimens (8mm in diameter × 4mm thickness) were prepared using five commercially available composites (n=10); two LCBF (XB-X-trafil Voco, FB-FiltekTM Bulk Fill), one DCBF (FU-Fill-upTM Coltene), and two CC (CE-Clearfil Majesty ES2, EQ-Estelite ΣQuick). Initial and final color readouts were measured with a spectrophotometer (Easyshade,Vita) according to the CIELAB color system. Statistical analyses were performed using 2-way ANOVA with Bonferroni adjustment to evaluate ΔE, ΔL, Δa, and Δb parameters (pFB≥XB>EQ≥CE in water immersion groups and XB>FB>EQ≥FU≥CE in coffee immersion groups. Conclusion: Within the limitations of this study, DCBF composite is more susceptible to intrinsic discoloration compared to LCBF and CC. However, DCBF exhibited lower extrinsic discoloration than LCBF and comparable with CC after coffee immersion. Depending on their chemical and structural compositions, composites will exhibit color change, which compromises the esthetic performance of composite restorations.


RESUMEN: Propósito: El propósito de este estudio fue evaluar la decoloración de resinas bulk de curado dual (DCBF) y bulk activadas por fotopolimerización (LCBF) en relación con las resinas convencionales (CC) después de la inmersión en agua y café. Métodos: Se prepararon cien muestras en forma de disco (8mm de diámetro × 4mm de espesor) utilizando cinco resinas compuestas disponibles comercialmente (n=10); dos LCBF (XB-X-trafil Voco, FB-FiltekTM Bulk Fill), un DCBF (FU-Fill-upTM Coltene) y dos CC (CE-Clearfil Majesty ES2, EQ-Estelite ΣQuick). Las lecturas de color inicial y final se midieron con un espectrofotómetro (Easyshade, Vita) de acuerdo con el sistema de color CIELAB. Los análisis estadísticos se realizaron utilizando ANOVA de 2 vías con ajuste de Bonferroni para evaluar los parámetros ΔE, ΔL, Δa y Δb (pFB≥XB>EQ≥CE en los grupos de inmersión en agua y XB>FB>EQ≥FU≥CE en los grupos de inmersión en café. Conclusión: Dentro de las limitaciones de este estudio, la resina DCBF es más susceptible a la decoloración intrínseca en comparación con LCBF y CC. Sin embargo, DCBF mostró una decoloración extrínseca más baja que LCBF y comparable con CC después de la inmersión en café. Dependiendo de sus composiciones químicas y estructurales, los composites mostrarán cambios de color, lo que compromete el desempeño estético de las restauraciones de resinas con el tiempo.


Subject(s)
Tooth Discoloration , Composite Resins/analysis
8.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386541

ABSTRACT

ABSTRACT: Objective: The aim of this study was to evaluate and compare the effects of the superficial application of two different modeling resins on the surface microhardness and discoloration of composite resins. Material and Methods: The present study used two different composites and modeling resins. The composites were placed in plastic molds. Subsequently, the modeling resins were applied on the surface of the two composite groups. The microhardness and color pertaining to all the groups were evaluated. The current study used the One-Way ANOVA and Kruskal Wallis tests, in order to perform the statistical evaluation (p<0.05). Results: The present study compared the microhardness pertaining to the groups and the highest microhardness values were observed in the Estelite Asteria group (none), whereas the lowest values were observed in the GC Essentia group (Ultradent). Moreover, the current study evaluated the color stability and the greatest discoloration was observed in the control group of the GC Essentia group, whereas the least discoloration was observed in the Estelite Asteria group that included the samples prepared using Ultradent Wetting Resin. Conclusions: The results of the present study demonstrated that the use of modeling resins, which facilitate the placement of composite resins, reduced the microhardness and discoloration of composite resins. The aforementioned effect can be attributed to the variations in the structure of the filling. However, further studies are warranted to support and verify the results of the current study.


RESUMEN: Objetivo: El objetivo del presente estudio fue evaluar y comparar los efectos de la aplicación superficial de dos resinas humectantes sobre la microdureza superficial y la decoloración de las resinas compuestas. Material y métodos: El presente estudio utilizó dos resinas humectantes y resinas de modelado diferentes. Las resinas compuestas se colocaron en moldes de plástico. Posteriormente, se aplicaron las resinas humectantes sobre la superficie de los dos grupos. Se evaluó la microdureza y el color de todos los grupos. El presente estudio utilizó las pruebas One-Way ANOVA y Kruskal Wallis, para realizar la evaluación estadística (p<0.05). Resultados: Los valores más altos de microdureza se observaron en el grupo Estelite Asteria, mientras que los menores valores se observaron en el grupo GC Essentia (Ultradent). La mayor decoloración se observó en el grupo control o el grupo GC Essentia, mientras que la menor decoloración se observó en el grupo Estelite Asteria con Ultradent Wetting Resin. Conclusiones: Los resultados del presente estudio demostraron que el uso de resinas humectantes, que facilitan la colocación de resinas compuestas, redujo la microdureza y decoloración de las resinas compuestas. El efecto mencionado anteriormente se puede atribuir a las variaciones en la estructura del relleno. Sin embargo, se necesitan más estudios para respaldar y verificar los resultados del presente estudio.


Subject(s)
Composite Resins/analysis , Hardness , Hardness Tests , Tooth Discoloration , Turkey
9.
Odovtos (En línea) ; 23(1)abr. 2021.
Article in English | LILACS, SaludCR | ID: biblio-1386521

ABSTRACT

Abstract: Objective: This study investigated the effects of three types of mouthwash on the color stability of three resin-based restorative materials (nanohybrid resin composite, sonic-activated bulk-fill material, and compomer). Materials and Methods: To this end, 120 cylindrical disc specimens were prepared and polished, after which they were incubated in distilled water for 24 hours for post-polymerization. The baseline color values of each specimen were measured with a spectrophotometer, then the specimens were randomly divided into four groups. Following immersion in the mouthwashes for 24 hours, the specimens were rinsed with distilled water and dried before the color measurement was repeated. The values of color change (ΔE₀₀) were subsequently calculated. A two-way analysis of variance and Duncan's post hoc multiple comparison tests were conducted to determine statistically significant differences among the restorative materials. Results: All samples showed discoloration after immersion, albeit some instances of discoloration were imperceptible. In this respect, a statistically significant difference was found among the restorative materials and mouthwashes (p<0.05). Imperceptible ΔE₀₀ values were derived on the nanohybrid resin composite and compomer, but perceptible and acceptable ΔE₀₀ values were detected on the sonic-activated bulk-fill materials (p<0.05). The clinically unacceptable discoloration was observed on the sonic-activated bulk-fill composite immersed in Listerine®. Conclusions: Clinicians should make recommendations based on the potential staining capacity of mouthwashes prescribed for daily use in restorative materials. In this way, the need for renewal of restorations due to discoloration could be avoided.


Resumen: Objetivo: Este estudio investigó los efectos de tres tipos de enjuague bucal en la estabilidad del color de tres materiales de restauración a base de resina (resina nanohíbrida, resina bulk-fill de activación sónica y compómero). Materiales y Métodos: Para ello se prepararon y pulieron 120 muestras de discos cilíndricos, después de lo cual se incubaron en agua destilada durante 24 horas pospolimerización. Los valores de color de base de cada muestra se midieron con un espectrofotómetro, después las muestras se dividieron aleatoriamente en cuatro grupos. Tras la inmersión en los enjuagues bucales durante 24 horas, los especímenes se enjuagaron con agua destilada y se secaron antes de repetir la medición del color. Posteriormente se calcularon los valores de cambio de color (ΔE₀₀). Se llevó a cabo un análisis bidireccional de la varianza y las pruebas de comparación múltiple post hoc de Duncan para determinar las diferencias estadísticamente significativas entre los materiales de restauración. Resultados: Todas las muestras mostraron decoloración después de la inmersión, aunque algunos casos esta fue imperceptible. Se encontró una diferencia estadísticamente significativa entre los materiales de restauración y los enjuagues bucales (p<0,05). Se obtuvieron valores imperceptibles de ΔE₀₀ en el compuesto de resina nanohíbrida y el compómero, pero se detectaron valores perceptibles y aceptables de ΔE₀₀ en la resina bulk-fill activada sónicamente (p<0,05). Se observó una decoloración clínicamente inaceptable en la resina bulk-fill activada sónicamente inmersa en Listerine®. Conclusiones: Los clínicos deben hacer recomendaciones basadas en la capacidad potencial de coloración de los enjuagues bucales prescritos para uso diario en los materiales de restauración. De esta manera, se podría evitar la necesidad de renovar las restauraciones debido a la decoloración.


Subject(s)
Tooth Discoloration , Mouthwashes/analysis , Resins
10.
Braz. dent. sci ; 24(4, suppl 1): 1-9, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1352598

ABSTRACT

Objective: To compare the color stability and translucency of aged and unaged experimental zirconia reinforced rice husk nanohybrid composite resin (Zr-Hybrid) with a commercialized nanofilled and a microhybrid composite resin after immersion in four different infusion media. Material and Methods: Three groups of standardized disc-shaped composite resin with 80 samples per group were prepared as follow: Group 1 (Filtek-Z350-XT), Group 2 (Zmack-Comp), and Group 3 (Zr-Hybrid). Each group was further subdivided into aged (n=40) and unaged (n=40) groups. Initial color measurements were taken using a digital spectrophotometer based on CIE L*a*b* color system. Samples in aged subgroup were subjected to 2500 thermal cycles. Subsequently, all samples were immersed in four different types of infusion media (n=10): T1 - Distilled water, T2 - Soft drink, T3 - Tea and T4 - Coffee. After 15 days, color measurements of all samples were measured again. Data were analyzed using two-way ANOVA followed by Bonferroni and paired sample t-tests with a significance level set at P=0.05. Results: Unaged Zr-Hybrid showed comparable color change to Zmack-Comp and Filtek-Z350-XT (P=0.181), but aged Zr-Hybrid demonstrated the lowest color change (P<0.001). Zr-Hybrid exhibited the lowest translucency value (P<0.001), but no significant color and translucency changes (P=0.051 and P=0.069, respectively) were observed between unaged and aged Zr-Hybrid. Soft drink had the greatest effect (P<0.001) on color change, while coffee showed the greatest effect (P<0.001) on translucency. Conclusion: Although Zr-Hybrid showed greater opacity, it still retained its color stability and translucency after accelerated aging compared to commercialized microhybrid and nanofilled composite resins. All infusion media caused discoloration and affected the composite resins' translucency. (AU)


Objetivo: Comparar a estabilidade de cor e translucidez de uma resina composta nanohíbrida de casca de arroz reforçada com zircônia experimental envelhecida e não envelhecida (Zr-Hybrid) com uma resina composta comercial nanoparticulada e microhíbrida após a imersão em quatro meios de infusão diferentes. Material e Métodos: Três grupos de resina composta em forma de disco padronizado com 80 amostras por grupo foram preparados da seguinte forma: Grupo 1 (Filtek-Z350-XT), Grupo 2 (Zmack-Comp) e Grupo 3 (Zr-Hybrid). Cada grupo foi subdividido em grupos de envelhecimento (n = 40) e não envelhecimento (n = 40). As medições iniciais de cor foram feitas usando um espectrofotômetro digital baseado no sistema de cores CIE L * a * b *. As amostras do subgrupo envelhecido foram submetidas a 2500 ciclos térmicos. Posteriormente, todas as amostras foram imersas em quatro tipos diferentes de meios de infusão (n = 10): T1 - Água destilada, T2 - Refrigerante,T3 - Chá e T4 - Café. Após 15 dias, as medições de cor de todas as amostras foram medidas novamente. Os dados foram analisados usando ANOVA dois fatores seguido por Bonferroni e testes t pareados com nível de significância estabelecido em P = 0,05. Resultados: O grupo Zr-Hybrid não envelhecido mostrou uma mudança de cor comparável a Zmack-Comp e Filtek-Z350-XT (P = 0,181), mas o grupo Zr-Hybrid envelhecido demonstrou a menor mudança de cor (P <0,001). Zr-Hybrid exibiu o menor valor de translucidez (P <0,001), mas nenhuma mudança significativa de cor e translucidez (P = 0,051 e P = 0,069, respectivamente) foram observadas entre Zr-Hybrid não envelhecido e envelhecido. O refrigerante teve o maior efeito (P <0,001) na mudança de cor, enquanto o café apresentou o maior efeito (P <0,001) na translucidez. Conclusão: Apesar do grupo Zr-Hybrid tenha mostrado maior opacidade, ele ainda manteve sua estabilidade de cor e translucidez após envelhecimento acelerado em comparação com resinas compostas micro-híbridas e nanoparticuladas comercializadas. Todos os meios de infusão causaram descoloração e afetaram a translucidez das resinas compostas (AU)


Subject(s)
Spectrophotometers , Composite Resins
11.
Braz. dent. sci ; 24(4): 1-11, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1337554

ABSTRACT

Objective: TThe study evaluated in vitro the changes in roughness, color stability, and bacterial count of a CAD/CAM Resin Nano-Ceramic material surface treated by various scaling procedures. Material and Methods: 70 disks (5mm diameter, 0.5 mm thickness) of Resin Nano-Ceramic (Lava ™Ultimate, 3M, ESPE) material were cemented in standardized cavities prepared in bovine teeth. A custom-made scaling apparatus of a double pan balance was used for different scaling methods, simulating standard clinical conditions. The specimens were assigned to three main groups: no scaling(C), ultrasonic scaling (U), and manual scaling (M). Each group was then divided into three subgroups according to scaling tip material; stainless steel tip (St), plastic tip (P), and titanium tip (Ti). The surface texture was analyzed quantitatively and qualitatively with a tactile profilometer and atomic force microscopy. A spectrophotometer was used for color measurement. Streptococcus mutans were counted in a colony counter. All the data were tabulated and statistically analyzed. Results: Two-way ANOVA was used to study the effect while One-way ANOVA was performed to compare between study groups. The significance level was set at p ≤ 0.05. The ultrasonic titanium tip(UTi) revealed the significant highest mean value of alterations (p < 0.001). The integrity of the material surface was altered in the form of deep scratches on the ultrasonically scaled surfaces and numerous smaller scratches on the hand-scaled surfaces. Conclusion: The plastic instrument would appear to be the instrument of choice during a routine maintenance procedure for Resin Nano-Ceramic materials (AU).


Objetivo: Este estudo avaliou in vitro as alterações na rugosidade, estabilidade de cor e quantidade de bactérias da superfície de uma resina nano-cerâmica produzida em CAD/CAM tratada por diferentes procedimentos de raspagem. Material e Métodos: 70 discos (5 mm diâmetro, 0,5 espessura) de resina nano-cerâmica (Lava ™Ultimate, 3M, ESPE) foram cimentadas em cavidades padronizadas preparadas em dentes bovinos. Um aparato customizado de raspagem com pratos duplos de balança foram usados para os diferentes métodos de raspagem, simulando uma condição clínica padronizada. Os espécimes foram distribuídos em três principais grupos: Sem raspagem (C), raspagem ultrassônica (U) e raspagem manual (M). Cada grupo foi dividido em três subgrupos de acordo com a ponta do material de raspagem; ponta de aço inoxidável (St), ponta plástica (P), ponta de titânio (Ti). A textura da superfície foi analisada qualitativamente e quantitativamente por um perfilômetro tátil e microscopia de força atômica. Um espectrofotometro foi usado para a mensuração da cor. Estreptococos mutans foram contados em um contador de colônias. Todos os dados foram tabulados e analisados estatisticamente. Resultados: Anova dois fatores foi utilizado para estudar os efeitos, enquanto ANOVA um fator foi utilizado para comparar os grupos experimentais. O nível de significância foi estabelecido em p≤ 0,05. A ponta de ultrassom de titânio (UTi) revelou o valor significante mais alto de alterações (p < 0,001). A integridade da superfície d matérias foi alterada na forma ranhuras profundas, nas superfícies raspada por ultrassom e numerosas ranhuras menores nas superfícies raspadas à mão. Conclusão: O instrumento plástico poderia apresentar-se como um instrumento de escolha durante o pocedimento de manutenção routineira para materiais de resina nano-ceramica. (AU)


Subject(s)
Dental Scaling , Resin Cements , Dental Plaque
12.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 515-522, 2021.
Article in Chinese | WPRIM | ID: wpr-877207

ABSTRACT

Objective@#To compare the color stability of Biodentine and mineral trioxide aggregate (MTA) within the blood environment in vitro and to further investigate the underlying reasons for such color instability. @*Methods @#We first generated Biodentine and MTA discs with a diameter of 5 mm and a height of 3 mm. 24 discs of each material were randomly divided into two groups: the deionized water group and the defibrinated sheep blood group. Discs of each group were immersed for 1 day or 7 days before assessments. First, all discs were photographed to directly compare the discoloration of Biodentine and MTA. The color degree of the two materials was tested by a spectrophotometer. Then, the high-resolution morphological characteristics were observed by scanning electron microscopy. Finally, the chemical contents of each element in the material were measured by energy-dispersive spectroscopy.@*Results @#Compared to immediately after stripping, a change in the brightness of discs after immersion in defibrinated sheep blood for 1 day was observed only in MTA. On the 7th day after being immersed in blood, the colors of both the Biodentine and MTA discs darkened and turned deep red, but the darkness of the MTA discs increased significantly. The color change of MTA immersed in blood was measured on a spectrophotometer with a greater 7-day ∆E (21.257 ± 0.955) than the Biodentine 7-day ∆E (5.833 ± 0.501) (t=24.781, P < 0.001). MTA exhibits more discoloration as the immersion time goes on. A significant difference was noted between the 1-day ∆E(6.233 ± 0.888) and the 7-day ∆E(t=19.956, P < 0.001) of MTA immersed in blood. However, there was no statistically significant difference between the 1-day ∆E (6.790 ± 0.831) and the 7-day ∆E(t=1.707, P=0.163) of Biodentine immersed in blood. It was observed by scanning electron microscopy that after 7 days of immersion in the defibrinated sheep ablood, the surface porosity of MTA was larger than that of Biodentine, and the crystal edge of MTA became rounded and blunt. The analysis by energy-dispersive X-ray spectroscopy showed that the oxygen content decreased and the bismuth content increased in MTA after immersion in defibrinated sheep blood for 7 days. Zirconium was not detected in Biodentine due to its low radiodensity, but the contents of other elements were stable in Biodentine after immersion in defibrinated sheep blood for 7 days. @* Conclusion@#The color stability of Biodentine within the blood environment is better than that of MTA in vitro, which is mainly related to the low surface porosity and stable composition of the anti-radiation agent of Biodentine.

13.
Odovtos (En línea) ; 22(2)ago. 2020.
Article in English | LILACS, SaludCR | ID: biblio-1386480

ABSTRACT

Abstract: Aim: Sufficient polymerization remains as crucial for composites to prevent discoloration. Both LEDs and halogen units are used for polymerization and different curing modes are improved to overcome inadequate polymerization. This in vitro study investigated staining susceptibility of a nano-hybrid resin composite light-cured in different modes and immersed in different staining media. Methods: Disc-shaped specimens were prepared from nano-hybrid resin composite (Filtek Z550) and light- cured according to following modes: Halojen (GI), LED standard (GII), LED pulse (GIII) or LED ramp (GIV). Half of the specimens of each group (n=7) were stored in one of the staining media (red wine or coffee) for 10 min/day during experimental period. Measurements were performed using spectrophotometer according to CIEL*a*b system at baseline and on 7, 28 and 56 days. Colour differences (∆E) between groups were submitted to statistical analysis. Results: Regarding 7-day evaluation, colour change values of specimens immersed in coffee revealed no remarkable difference among curing modes (p>0.05); whereas specimens in GIV were significantly less stained compared to specimens in GII and GIII when immersed in red wine. Regarding 56- days of evaluation, specimens of GIV showed statistically significant colour change in red wine compared to other groups. However specimens in GI revealed the least staining after 56-days of coffee immersion, and this result was statistically different from LED groups. Conclusion: This study suggest that light-curing mode influences the staining susceptibility of the tested composite. Composites polymerized with halogen unit showed lower staining than all LED modes. Despite novel light sources, halogen units may still used reliably at clinics.


Resumen: Objetivo: La polimerización suficiente sigue siendo crucial para que los compuestos eviten la decoloración. Tanto los LED como las unidades halógenas se utilizan para la polimerización y se mejoran los diferentes modos de curado para superar la polimerización inadecuada. Este estudio in vitro investigó la susceptibilidad a la tinción de un compuesto de resina nano-híbrida curado a la luz en diferentes modos y se sumergió en diferentes medios de tinción. Métodos: Las muestras en forma de disco se prepararon a partir de un compuesto de resina nano-híbrida (Filtek Z550) y se curaron con luz de acuerdo con los siguientes modos: Halojen (GI), estándar de LED (GII), pulso de LED (GIII) o rampa de LED (GIV). La mitad de las muestras de cada grupo (n = 7) se almacenaron en uno de los medios de tinción (vino tinto o café) durante 10 minutos / día durante el período experimental. Las mediciones se realizaron utilizando un espectrofotómetro de acuerdo con el sistema CIEL * a * b en la línea de base y en 7, 28 y 56 días. Las diferencias de color (∆E) entre los grupos se sometieron a análisis estadístico. Resultados: Con respecto a la evaluación de 7 días, los valores de cambio de color de las muestras sumergidas en café no revelaron diferencias notables entre los modos de curado (p> 0.05); mientras que las muestras en GIV se tiñeron significativamente menos en comparación con las muestras en GII y GIII cuando se sumergieron en vino tinto. Con respecto a los 56 días de evaluación, las muestras de GIV mostraron un cambio de color estadísticamente significativo en el vino tinto en comparación con otros grupos. Sin embargo, las muestras en GI revelaron la menor tinción después de 56 días de inmersión en el café, y este resultado fue estadísticamente diferente de los grupos LED. Conclusión: este estudio sugiere que el modo de fotopolimerización influye en la susceptibilidad de tinción del material compuesto probado. Los compuestos polimerizados con una unidad halógena mostraron una tinción más baja que todos los modos LED. A pesar de las nuevas fuentes de luz, las unidades halógenas todavía pueden usarse de manera confiable en las clínicas.


Subject(s)
Tooth Discoloration/diagnosis , Composite Resins , Light-Curing of Dental Adhesives/instrumentation
14.
Braz. dent. j ; 31(1): 69-77, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1089271

ABSTRACT

Abstract The objective was to evaluate the color stability of ceramic veneers luted with resin cements and pre-heated composite resins (60oC) for 12 months, and determine the degree of conversion (DC) of the luting agents. Two resin cements (AllCem Veneer, light-cured (LRC) and AllCem, dual-cured (DRC)] and three composite resins [Z100 (MNCR-minifilled), Herculite Classic (MHCR-micro-hybrid) and Durafill (MCCR-microfilled)] were used for cementing 0.8-mm-thick lithium-silicate glass-ceramic laminates (Suprinity, shade B2-HT, Vita) on bovine enamel (n=10). The specimens were stored at 37oC in distilled water. CIELab parameters were determined at 24h after luting (baseline), 7, 30, 90, 180 days and 12 months. Three specimens were prepared for DC evaluation, performed by micro-Raman spectroscopy. Data were analyzed by ANOVA and Tukey's test (a=5%). For ΔEab and ΔE00, there were significant differences for luting material (p<0.001), time (p<0.001), and double interaction (p<0.001). The groups cemented with MHCR (1 year), MCCR (90 days and 1 year) and MCCR-PH (1 year) were the ones with ΔE values greater than the acceptability threshold. All other groups maintained their ΔE lower than the acceptability threshold after 1 year in distilled water. Regarding DC, there were no significant differences (p=0.127) among the materials. Non-significant negative correlations were observed between the mean ΔEab and DC (R=-0.65) and ΔE00 and DC (R=-0.64). A significant positive correlation was observed mean ΔEab and ΔE00 (R=0.99). It was concluded that the different luting agents influenced the final color of the restorations. The heating of the composite resins did not affect their DC.


Resumo O objetivo foi avaliar a estabilidade de cor de laminados cerâmicos de fina espessura, após a cimentação com cimentos resinosos e resinas compostas em temperatura ambiente e aquecida (60oC), durante 12 meses; bem como determinar o grau de conversão dos diferentes materiais para cimentação. Foram utilizados dois cimentos resinosos [AllCem Veneer, cimento resinoso fotoativado (LRC) e AllCem, cimento resinoso dual (DRC)] e três resinas compostas [Z100 (MNCR - resina composta de partículas finas), Herculite Classic (MHCR - resina composta micro-híbrida) e Durafill (MCCR - resina composta microparticulada)] para cimentação de laminados cerâmicos a base de silicato de lítio (Suprinity, cor B2-HT, Vita Zahnfabrik) com 0,8 mm de espessura, sobre esmalte bovino. Oitenta espécimes foram distribuídos aleatoriamente em 8 grupos de acordo com o material para cimentante (n=10). Os espécimes foram armazenados a 37oC em água destilada. Os parâmetros do CIELab foram determinados 24h após a cimentação (baseline), 7, 30, 90, 180 dias e 12 meses. Outros três espécimes foram preparados para avaliação de grau de conversão, realizada por espectroscopia micro-Raman. Os dados foram analisados por ANOVA e teste de Tukey (a=5%). Para ΔEab e ΔE00, houve diferenças estatisticamente significantes para o material de cimentação (p<0,001), tempo (p<0,001) e interação dupla (p<0,001). Os grupos cimentados com o MHCR (1 ano), MCCR (90 dias e 1 ano) e MCCR-PH (1 ano) foram os únicos com valores de ΔE maiores que o limite de aceitabilidade. Todos os demais grupos mantiveram seu ΔE menor que o limite de aceitabilidade ao final de 1 ano de armazenamento em água destilada. Em relação ao grau de conversão, não foram observadas diferenças estatisticamente significantes entre os materiais para cimentação avaliados (p=0,127). O grau de conversão variou entre 64,0% (MNCR-PH) e 85,1% (DRC). Correlações negativas moderadas a fortes não significativas foram observadas entre a média ΔEab e grau de conversão (R=-0,65) e ΔE00 e grau de conversão (R=-0,64). Observou-se uma correlação positiva forte significativa nos valores médios de ΔEab e ΔE00 (R=0,99). Pode-se concluir que os diferentes agentes cimentantes utilizados na cimentação de laminados cerâmicos de espessura fina influenciaram na cor final das restaurações. O aquecimento das resinas compostas não implicou em alteração do grau de conversão.


Subject(s)
Animals , Ceramics , Resin Cements , Materials Testing , Cattle , Follow-Up Studies , Color , Composite Resins , Dental Porcelain , Dental Veneers
15.
The Journal of Korean Academy of Prosthodontics ; : 1-6, 2020.
Article in English | WPRIM | ID: wpr-786599

ABSTRACT

PURPOSE: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants.MATERIALS AND METHODS: Four types of conventional prefabricated denture teeth (Surpass, GC, Artic 6, Heraeus Kulzer, Premium 6, Heraeus Kulzer, Preference, Candulor), 3D-printed denture teeth (Dentca); and Z250 (Filtek Z250, 3M ESPE) were prepared for testing. The samples were immersed in erythrosine 3%, coffee, cola, and distilled water (DW) at 37℃. Color change (ΔE) was measured by spectrophotometer before immersion and at 7, 14, and 21 days after immersion. One-way analysis of variance was performed along with Tukey's honestly significant difference multiple comparisons test (P<.05).RESULTS: No great difference was observed between the color change of Dentca denture teeth and that of conventional denture teeth in most cases (P>.05). The color change of Dentca denture teeth immersed in erythrosine 3% was greater than that of Surpass (ΔE = 0.67 ± 0.25) after 1 week; Artic 6 (ΔE = 1.44 ± 0.38) and Premium 6 (ΔE = 1.69 ± 0.35) after 2 weeks; and Surpass (ΔE = 1.79 ± 0.49), Artic 6 (ΔE = 2.07 ± 0.21), Premium 6 (ΔE = 2.03 ± 0.75), and Preference (ΔE = 2.01 ± 0.75) after 3 weeks (P<.05).CONCLUSION: A color change was observed in Dentca denture teeth when immersed in some colorants; however, the maximum value of ΔE for Dentca denture teeth was within the clinically acceptable range.


Subject(s)
Coffee , Cola , Dentures , Erythrosine , Immersion , Printing, Three-Dimensional , Tooth , Water
16.
Braz. dent. j ; 30(3): 259-265, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011543

ABSTRACT

Abstract The objective was to evaluate the color stability of thin ceramic veneers as a function of the curing mode (with and without pre-cure) of different adhesive systems applied to the internal surface of ceramics. Five adhesive systems (Scotchbond Multi-Purpose, Single Bond Universal, Gluma 2 Bond, Ambar, and Ambar APS) and photo-cured resin cement (Allcem Veneer) were used for cementing 0.6 mm-thick feldspathic veneers (Mark II) on composite resin substrates (Charisma Diamond). The groups, according to adhesive system, were divided into two subgroups (n=10): i) adhesive and resin cement were polymerized separately (pre-cure of the adhesive), ii) adhesive and resin cement were polymerized simultaneously. The CIELab color parameters were determined with a spectrophotometer at 24h (baseline), 7 days, 30 days and 12 months. Data were analyzed by two-way ANOVA and Tukey's test (α=0.05). The results indicated statistically significant differences for adhesive systems and time. The mode of curing of the adhesive system was not statistically significant: pre-cured adhesives (2.6±1.3) and not pre-cured adhesives (2.8±1.4). For the adhesives, ΔE values varied in the following order: Ambar-APS (1.6±0.5) < Scotchbond Multi-Purpose (2.6±1.2) = Gluma 2 Bond (2.7±1.2) = Ambar (2.9±1.2) < Single Bond Universal (3.5±1.5). For time, ΔE values were: 7 days (1.7±0.7), 30 days (3.5±1.2) and 12 months (2.9±1.3). It can be concluded that the different adhesive systems used for cementing thin ceramic veneers influenced the final color of the indirect restorations. The adhesives curing mode did not present a significant effect in the color stability of thin ceramic veneers.


Resumo O objetivo deste estudo foi avaliar a estabilidade de cor de laminados cerâmicos de espessura fina em função do momento de ativação de diferentes sistemas adesivos na superfície interna das cerâmicas. Foram utilizados 5 sistemas adesivos (Scotchbond Multiuso, Single Bond Universal, Gluma 2 Bond, Ambar and Ambar APS) e o cimento resinoso fotoativado (Allcem Veneer) para cimentação de lâminas de cerâmica feldspática (Mark II) com 0,6 mm de espessura, sobre substratos de resina composta (Charisma Diamond). Os grupos, de acordo com o sistema adesivo utilizado, foram divididos em dois subgrupos (n=10): i) adesivo e cimento resinoso foram polimerizados separadamente (polimerização isolada do adesivo), ii) adesivo e cimento resinoso foram polimerizados ao mesmo tempo (polimerização simultânea). Os parâmetros de cor do sistema CIELab foram determinados com um espectrofotômetro nos tempos de 24 h (baseline), 7 dias, 30 dias e 12 meses. Os dados foram analisados por ANOVA a dois fatores e teste de Tukey (α=0,05). Os resultados indicaram diferenças estatísticas significantes para os sistemas adesivos e tempo. O momento da fotoativação do sistema adesivo não foi estatisticamente significante: polimerização prévia (2,6±1,3) e polimerização simultânea (2,8±1,4). Para o sistema adesivo, os valores médios de ΔE variaram na seguinte ordem: Ambar APS (1,6±0,5)<Scotchbond Multi-Purpose (2,6±1,2)=Gluma 2 Bond (2,7±1,2)=Ambar (2,9±1,2)<Single Bond Universal (3,5±1,5). Para o fator tempo o ΔE foi: 7 dias (1,7±0,7), 30 dias (3,5±1,2) e 12 meses (2,9±1,3). Pode-se concluir que os diferentes sistemas adesivos utilizados na cimentação de laminados cerâmicos de espessura fina influenciaram na cor final das restaurações. O momento da fotoativação, isolada ou simultânea ao cimento resinoso, não apresentou efeito significativo na estabilidade de cor dos laminados cerâmicos de espessura fina.


Subject(s)
Dental Cements , Dental Veneers , Materials Testing , Ceramics , Color , Resin Cements , Light-Curing of Dental Adhesives
17.
Article | IMSEAR | ID: sea-210085

ABSTRACT

This study investigated the color stability of reline resin after two methods of disinfection i.e microwave disinfection and chemical disinfection. A stainless steel moldwith a breakaway compartment (10 mm in diameter by 0.7 mm thickness) was made to fabricate specimens of various resins. Each material was mixed according to manufacturer’s instructions and applied into the mold. Prior to color stability testing, specimenswere cleaned in distilled water for 20 minutes to kill any microorganisms that may had contaminated the discs during fabrication. And then specimens were immersed in Sodium Perborate Monohydrate 200 ml of solution for 15 days and microwaved for 15 days sothat it is comparable to chemical disinfection soaking. The color stability of each specimen was measured again using spectrophotometer and values were obtained. The data of ∆E, ∆L, ∆b, ∆a were analysed by 2 way repeated measures ANOVAs test. Significant statistic changes in color parameters ∆L, ∆a, ∆b of the reline resin DPI, Ufi Gel Hard And Kooliner were observed when dentures were disinfected by Sodium Perborate Monohydrate 2% solutions. The color stability of the reline resin was influenced by time, regardless of disinfection or non disinfection. This can be attributed to bleaching (whitening) effect of reline material. Discoloration Original Research Article of resin based materials may be caused by intrinsic or extrinsic factors. Intrinsic factors are related to internal alterations in material resulting from physicochemical reactions or residual monomer oxidation with time. Thus the initiator, quantity and type of monomer and the polymerisation efficiency can affect the color stability of resin based materials. The color stability deviation value ∆E significantly increased to maximum for chemical disinfectant, least for Control group and intermediate for microwaved group. Ufi Gel showed the highest deviation ∆E and Control Group showed the lowest deviation according to results

18.
Braz. dent. j ; 30(1): 52-57, Jan.-Feb. 2019. tab
Article in English | LILACS | ID: biblio-989428

ABSTRACT

Abstract This study evaluated gloss and color changes of esthetic restorative materials subjected to different acidic beverages. Specimens of resin composites (Z350XT (Z350), IPS Empress Direct (ED), Charisma Diamond (CD)) were prepared and the initial surface gloss and color (ΔE) were measured (n=10). Then, the specimens were immersed in 4 mL of each of the different beverages (cranberry juice; Coca-Cola; coffee or artificial saliva) during 15 min, 3x/day for 14 days and new gloss and color readings were obtained. Color change was evaluated with the ΔE formula and gloss change values were obtained by the formula: (final gloss - initial gloss). Data was submitted to two-way ANOVA followed by Tukey's post hoc test (a=0.05). CD showed the lowest color change among resin composites. The highest ΔE values were obtained after immersion in coffee and cranberry juice. Coffee promoted the highest gloss change (worst gloss retention), followed by cranberry juice, Coca-cola and artificial saliva (p<0.05). The type of beverage significantly influenced the gloss of resin composites. Coca-cola reduced gloss of the three resin composites in a similar manner. Coffee affected the ED gloss more than that of Z350 and CD, while cranberry juice affected Z350 more than ED and CD. Saliva had a more pronounced effect on the gloss retention of CD than ED. The beverages used in this study influenced the optical surface properties of the composites studied.


Resumo O objetivo foi avaliar as alterações de brilho e cor de materiais restauradores estéticos submetidos ao armazenamento em diferentes bebidas ácidas. Foram preparados espécimes de compósitos de resina (Z350XT (Z350), IPS Empress Direct (ED), Charisma Diamond (CD) e o brilho e a cor (ΔE) de superfície mensurados (n=10). Em seguida, os espécimes foram imersos em 4 mL de cada uma das diferentes bebidas (suco cranberry, Coca-Cola, café, ou saliva artificial) durante 15 min, 3x/dia durante 14 dias e o brilho e a cor novamente mensurados. A alteração de cor foi avaliada pela fórmula ΔE e os valores de alteração de brilho foram obtidos pela fórmula: (brilho final - brilho inicial). Os dados foram submetidos à ANOVA e Tukey (a = 0,05). CD apresentou menor alteração de cor quando comparado aos demais compósitos e maiores valores de ΔE foram obtidos após imersão em suco de café e cranberry. O café promoveu maior perda de brilho, seguido pelo suco cranberry, Coca-cola e saliva artificial (p <0,05). O tipo de bebida influenciou significativamente no brilho dos compósitos resinosos. Coca-cola reduziu o brilho dos três compósitos de maneira similar. O café promoveu maior alteração do brilho do ED, quando comparado ao Z350 e CD, enquanto o suco de cranberry afetou mais o Z350 do que o ED e o CD. A saliva teve efeito mais significativo na perda do brilho do CD do que o ED. As bebidas utilizadas neste estudo influenciaram as propriedades ópticas de superfície dos compósitos.


Subject(s)
Color , Dental Materials , Dental Restoration, Permanent , Esthetics, Dental , Spectrophotometry/methods , Surface Properties , Beverages
19.
Korean Journal of Dental Materials ; (4): 109-120, 2019.
Article in Korean | WPRIM | ID: wpr-750283

ABSTRACT

The purpose of this study was to evaluate the color stability of light cured composite resins according to the resin matrices. Three kinds of resin matrices such as Bis-GMA (Venus® Diamond; VD), Silorane (FiltekTM P90; P90), and Ormocer (Admira; Ad) were selected. Each of them were used to prepare 30 specimens. The initial CIE L*a*b* values were measured by means of a Spectrophotometer (NF999, Nippon Denshoku, Japan). For accelerated aging process, the specimens were immersed in a circulating water bath with distilled water at 60℃. Spectrophotometric analyses were made after immersion of 8, 16, 24, 41 days and the color difference (ΔE*) was calculated. The L* value increased compared with initial L* value. VD had the greatest L* value change and Ad had the smallest L* value change (p<0.05). Ad had the greatest a* value change and VD had the smallest a* value change (p<0.05). The b* value of P90 increased steadily in positive value (+)(p<0.05). ΔE* of Ad had the smallest value and that of P90 had the greatest change with time. According to this study, the value of light cured composite resins was increased with water sorption and color of those changed into greenish and yellowish. And according to the evaluation of color stability, Ad with Ormocer as resin matrices had the best color stability with time in oral environment and P90 with Silorane as resin matrices had the lowest color stability with time. And VD had the greatest initial ΔE*.


Subject(s)
Aging , Baths , Bisphenol A-Glycidyl Methacrylate , Composite Resins , Diamond , Immersion , Organically Modified Ceramics , Silorane Resins , Water
20.
Korean Journal of Dental Materials ; (4): 11-20, 2019.
Article in Korean | WPRIM | ID: wpr-750280

ABSTRACT

Objective of this study was to compare the color stability, mechanical and chemical properties of three different types of temporary crown resins. Commercially available powder-liquid (Group PL), light-cured (Group LC) and auto-mix syringe (Group AM) types' temporary crown resins were used as experimental groups for each of the evaluation. All the test groups were evaluated after 1 day and 7 days of immersion in various staining solutions. The colors of all groups before and after storage in the staining solutions were measured by a spectrophotometer based on CIE Lab system, and the color differences (ΔE(*)) thereby calculated. Micro hardness test was performed before water storage and aging after 7 days at 37 ℃. In addition, flexural strength, water sorption and solubility tests were performed according to international standard, ISO 10477. All experimental groups showed significant color change in staining solutions when compared to those stored in the control solution (distilled water) (p PL > LC (p<0.05). Water sorption and solubility increased in the following order: AM < PL < LC (p<0.05). The results of this study would provide useful information when choosing temporary crown resin types in various clinical situations.


Subject(s)
Aging , Crowns , Hardness Tests , Immersion , Solubility , Syringes , Water
SELECTION OF CITATIONS
SEARCH DETAIL